AND
Ä«½º
ºÀ½Å

 anired06_down.gif ·Îµå¼¿(Tension)  Model : TR Series                                                    Á¦Á¶»ç : ºÀ½Å






 

 anired06_down.gif  Á¦Ç°ÀÇ Æ¯Â¡

 

anisquare19_green.gif The TR series load cells are designed for measuring
    tensile loads up to 20 tonnes are particular y suited
    for industial application where optimum precision is
    needed.Featuring high-alloy tool steel construction
    for excellent repeatability, the unique element design
    provides high rated output (3mV/V) with low deflection.
    It is recommended that the load cell should incorporate
    rod end ball joint assemblies to reduce the overall length.
anisquare19_green.gif Hermetically sealed
anisquare19_green.gif Robust high capacity design
anisquare19_green.gif High rated output (3mV/V)
 

Model

TRU

TRC

TRD

Rated capacity (R.C.)

PT 1/2  50, 100, 200, 300, 500Kg, 1, 2, 3, 5, 10, 20t

Rated output (R.O.)

3mV/V ±0.1%

3mV/V ±0.5%

Non-linearity

¡Â0.02% R.O.

¡Â0.05% R.O.

¡Â0.1% R.O.

Hysteresis

¡Â0.02% R.O.

¡Â0.1% R.O.

Non-repeatability

¡Â0.02% R.O.

¡Â0.1% R.O.

Creep error

¡Â0.02% in 20min.

¡Â0.1% in 20min.

Zero balance

¡Â1% R.O.

Compensated temperature range

-10 ~ 70¡É

Operating temperature range

-20 ~ 80¡É

Temp. effect on rated output

¡Â0.03% LOAD/10¡É

¡Â0.05% LOAD/10¡É

Temp. effect on zero balance

¡Â0.03% R.O./10¡É

¡Â0.05% R.O./10¡É

              Terminal input resistance      

350 Ohms ±3.5 Ohms

Terminal output resistance

350 Ohms ±5 Ohms

Insulation resistance (Min.)

5000 MOhms at 50V DC

2000 MOhms at 50V DC

Excitation Voltage

10V(Recommended), 15V(Maximun)

Electrial connection

Ø9mmx3m (22AWG x 4Core Shielded)

Protection class

meets IP 67

Safe overload

150% R.C

Ultimate overload

300% R.C